NIOSH logo and tagline

Cyhexatin

Synonyms & Trade Names
TCHH, Tricyclohexylhydroxystannane, Tricyclohexylhydroxytin, Tricyclohexylstannium hydroxide, Tricyclohexyltin hydroxide
CAS No.
13121-70-5
RTECS No.
DOT ID & Guide
Formula
(C₆H₁₁)₃SnOH
Conversion
IDLH
80 mg/m3 [25 mg/m3 (as Sn)]
See: IDLH INDEX
Exposure Limits
NIOSH REL
TWA 5 mg/m3
OSHA PEL
TWA 0.32 mg/m3 [0.1 mg/m3 (as Sn)] See Appendix G
Measurement Methods
NIOSH 5504
See: NMAM or OSHA Methods
Physical Description
Colorless to white, nearly odorless, crystalline powder. [insecticide]
Molecular Weight
385.2
Boiling Point
442°F (Decomposes)
Melting Point
383°F
Solubility
Insoluble
Vapor Pressure
0 mmHg (approx)
Ionization Potential
NA
Specific Gravity
?
Flash Point
NA
Upper Explosive Limit
NA
Lower Explosive Limit
NA
Incompatibilities & Reactivities
Strong oxidizers, ultraviolet light
Exposure Routes
inhalation, skin absorption, ingestion, skin and/or eye contact
Symptoms
irritation eyes, skin, respiratory system; headache, dizziness; sore throat, cough; abdominal pain, vomiting; skin burns, pruritus; In Animals: liver, kidney damage
Target Organs
Eyes, skin, respiratory system, liver, kidneys
Personal Protection/Sanitation
(See protection codes)
Skin:Prevent skin contact
Eyes:No recommendation
Wash skin:When contaminated
Remove:When wet or contaminated
Change:Daily
First Aid
(See procedures)
Eye:Irrigate immediately
Skin:Soap wash immediately
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations

OSHA

Up to 3.2 mg/m3:
(APF = 10) Any air-purifying half-mask respirator with organic vapor cartridge(s) in combination with an N95, R95, or P95 filter. The following filters may also be used: N99, R99, P99, N100, R100, P100.
Click here for information on selection of N, R, or P filters.
(APF = 10) Any supplied-air respirator

Up to 8 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode
(APF = 25) Any powered, air-purifying respirator with an organic vapor cartridge in combination with a high-efficiency particulate filter.

Up to 16 mg/m3:
(APF = 50) Any air-purifying full-facepiece respirator equipped with organic vapor cartridge(s) in combination with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s) in combination with a high-efficiency particulate filter
(APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece

Up to 80 mg/m3:
(APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode

Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus

Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
Any appropriate escape-type, self-contained breathing apparatus

Important additional information about respirator selection

See also
Page last reviewed: October 30, 2019