NIOSH logo and tagline

Portland cement

Synonyms & Trade Names
Cement, Hydraulic cement, Portland cement silicate [Note: A class of hydraulic cements containing tri- and dicalcium silicate in addition to alumina, tricalcium aluminate, and iron oxide.]
CAS No.
65997-15-1
RTECS No.
DOT ID & Guide
Formula
Conversion
IDLH
5000 mg/m3
See: 65997151
Exposure Limits
NIOSH REL
TWA 10 mg/m3 (total) TWA 5 mg/m3 (resp)
OSHA PEL
TWA 50 mppcf See Appendix C (Mineral Dusts) See Appendix G
Measurement Methods
NIOSH 0500;
OSHA ID207
See: NMAM or OSHA Methods
Physical Description
Gray, odorless powder.
Molecular Weight
?
Boiling Point
NA
Melting Point
NA
Solubility
Insoluble
Vapor Pressure
0 mmHg (approx)
Ionization Potential
NA
Specific Gravity
?
Flash Point
NA
Upper Explosive Limit
NA
Lower Explosive Limit
NA
Noncombustible Solid
Incompatibilities & Reactivities
None reported
Exposure Routes
inhalation, ingestion, skin and/or eye contact
Symptoms
irritation eyes, skin, nose; cough, expectoration; exertional dyspnea (breathing difficulty), wheezing, chronic bronchitis; dermatitis
Target Organs
Eyes, skin, respiratory system
Personal Protection/Sanitation
(See protection codes)
Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated
Remove:When wet or contaminated
Change:No recommendation
First Aid
(See procedures)
Eye:Irrigate immediately
Skin:Soap wash promptly
Breathing:Fresh air
Swallow:Medical attention immediately
Respirator Recommendations

NIOSH

Up to 50 mg/m3:
(APF = 5) Any quarter-mask respirator.
Click here for information on selection of N, R, or P filters.

Up to 100 mg/m3:
(APF = 10) Any particulate respirator equipped with an N95, R95, or P95 filter (including N95, R95, and P95 filtering facepieces) except quarter-mask respirators. The following filters may also be used: N99, R99, P99, N100, R100, P100.
Click here for information on selection of N, R, or P filters.
(APF = 10) Any supplied-air respirator

Up to 250 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode
(APF = 25) Any powered, air-purifying respirator with a high-efficiency particulate filter.

Up to 500 mg/m3:


(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters. 


(APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece

Up to 5000 mg/m3:
(APF = 1000) Any supplied-air respirator operated in a pressure-demand or other positive-pressure mode

Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus

Escape:


(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters. 


Any appropriate escape-type, self-contained breathing apparatus

Important additional information about respirator selection

See also
INTRODUCTION   ICSC CARD: 1425   MEDICAL TESTS: 0196
Page last reviewed: October 30, 2019