NIOSH logo and tagline

Ferrovanadium dust

Synonyms & Trade Names
Ferrovanadium
CAS No.
12604-58-9
RTECS No.
DOT ID & Guide
Formula
FeV
Conversion
IDLH
500 mg/m3
See: 12604589
Exposure Limits
NIOSH REL
TWA 1 mg/m3 ST 3 mg/m3 [*Note: The REL also applies to Vanadium metal and Vanadium carbide.]
OSHA PEL
TWA 1 mg/m3 See Appendix G
Measurement Methods
OSHA ID121 , ID125G
See: NMAM or OSHA Methods
Physical Description
Dark, odorless particulate dispersed in air. [Note: Ferrovanadium metal is an alloy usually containing 50-80% vanadium.]
Molecular Weight
106.8
Boiling Point
?
Melting Point
2696-2768°F
Solubility
Insoluble
Vapor Pressure
0 mmHg (approx)
Ionization Potential
NA
Specific Gravity
?
Flash Point
NA
Upper Explosive Limit
NA
Lower Explosive Limit
NA
Minimum Explosive Concentration
1.3 g/m3
Metal: Noncombustible Solid, but dust may be an explosion hazard.
Incompatibilities & Reactivities
Strong oxidizers
Exposure Routes
inhalation, skin and/or eye contact
Symptoms
irritation eyes, respiratory system; In Animals: bronchitis, pneumonitis
Target Organs
Eyes, respiratory system
Personal Protection/Sanitation
(See protection codes)
Skin:No recommendation
Eyes:No recommendation
Wash skin:No recommendation
Remove:No recommendation
Change:No recommendation
First Aid
(See procedures)
Eye:Irrigate immediately

Breathing:Respiratory support
Respirator Recommendations

NIOSH/OSHA

Up to 5 mg/m3:
(APF = 5) Any quarter-mask respirator.
Click here for information on selection of N, R, or P filters.*

Up to 10 mg/m3:
(APF = 10) Any particulate respirator equipped with an N95, R95, or P95 filter (including N95, R95, and P95 filtering facepieces) except quarter-mask respirators. The following filters may also be used: N99, R99, P99, N100, R100, P100.
Click here for information on selection of N, R, or P filters.*
(APF = 10) Any supplied-air respirator*

Up to 25 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode*
(APF = 25) Any powered, air-purifying respirator with a high-efficiency particulate filter.*

Up to 50 mg/m3:


(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters. 


(APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode*
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter*
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece

Up to 500 mg/m3:
(APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode

Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus

Escape:


(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters. 


Any appropriate escape-type, self-contained breathing apparatus

Important additional information about respirator selection

See also
INTRODUCTION   MEDICAL TESTS: 0107