Ethylamine
NIOSH REL
TWA 10 ppm (18 mg/m3)OSHA PEL
TWA 10 ppm (18 mg/m3)Skin:Prevent skin contact (liquid)
Eyes:Prevent eye contact (liquid)
Wash skin:When contaminated (liquid)
Remove:When wet or contaminated (liquid)
Change:No recommendation
Provide:Eyewash (liquid), Quick drench (liquid)
Eye:Irrigate immediately (liquid)
Skin:Water flush immediately (liquid)
Breathing:Respiratory support
Swallow:Medical attention immediately (liquid)
NIOSH/OSHA
Up to 250 ppm:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode£
(APF = 25) Any powered, air-purifying respirator with cartridge(s) providing protection against the compound of concern£
Up to 500 ppm:
(APF = 50) Any chemical cartridge respirator with a full facepiece and cartridge(s) providing protection against the compound of concern
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted canister providing protection against the compound of concern
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Up to 600 ppm:
(APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted canister providing protection against the compound of concern
Any appropriate escape-type, self-contained breathing apparatus