NIOSH logo and tagline

1-Dodecanethiol

Synonyms & Trade Names
1-Dodecyl mercaptan, Dodecyl mercaptan, n-Dodecyl mercaptan, Lauryl mercaptan, n-Lauryl mercaptan, 1-Mercaptododecane
CAS No.
112-55-0
RTECS No.
DOT ID & Guide
1228 131
Formula
CH₃(CH₂)₁₁SH
Conversion
1 ppm = 8.28 mg/m3
IDLH
N.D.
See: IDLH INDEX
Exposure Limits
NIOSH REL
C 0.5 ppm (4.1 mg/m3) [15-minute]
OSHA PEL
none
Measurement Methods
None available
See: NMAM or OSHA Methods
Physical Description
Colorless, water-white, or pale-yellow, oily liquid with a mild, skunk-like odor. [Note: A solid below 15°F.]
Molecular Weight
202.4
Boiling Point
441-478°F
Freezing Point
15°F
Solubility
Insoluble
Vapor Pressure
(77°F): 3 mmHg
Ionization Potential
?
Specific Gravity
0.85
Flash Point
(oc) 190°F
Upper Explosive Limit
?
Lower Explosive Limit
?
Class IIIA Combustible Liquid: Fl.P. at or above 140°F and below 200°F.
Incompatibilities & Reactivities
Strong oxidizers & acids, strong bases, reducing agents, alkali metals, water, steam
Exposure Routes
inhalation, ingestion, skin and/or eye contact
Symptoms
irritation eyes, skin, respiratory system; cough; dizziness, dyspnea (breathing difficulty), lassitude (weakness, exhaustion), confusion, cyanosis; abdominal pain, nausea; skin sensitization
Target Organs
Eyes, skin, respiratory system, central nervous system, blood
Personal Protection/Sanitation
(See protection codes)
Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated
Remove:When wet or contaminated
Change:No recommendation
Provide:Eyewash
First Aid
(See procedures)
Eye:Irrigate immediately
Skin:Soap wash immediately
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations

NIOSH

Up to 5 ppm:
(APF = 10) Any chemical cartridge respirator with organic vapor cartridge(s)
(APF = 10) Any supplied-air respirator

Up to 12.5 ppm:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode
(APF = 25) Any powered, air-purifying respirator with organic vapor cartridge(s)

Up to 25 ppm:
(APF = 50) Any chemical cartridge respirator with a full facepiece and organic vapor cartridge(s)
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s)
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece

Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus

Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister
Any appropriate escape-type, self-contained breathing apparatus

Important additional information about respirator selection

See also
INTRODUCTION   ICSC CARD: 0042
Page last reviewed: October 30, 2019