NIOSH logo and tagline

n-Butyl glycidyl ether

Synonyms & Trade Names
BGE, 1,2-Epoxy-3-butoxypropane
CAS No.
2426-08-6
RTECS No.
DOT ID & Guide
Formula
C₇H₁₄O₂
Conversion
1 ppm = 5.33 mg/m3
IDLH
250 ppm
See: 2426086
Exposure Limits
NIOSH REL
C 5.6 ppm (30 mg/m3) [15-minute]
OSHA PEL
TWA 50 ppm (270 mg/m3) See Appendix G
Measurement Methods
NIOSH 1616;
OSHA 7
See: NMAM or OSHA Methods
Physical Description
Colorless liquid with an irritating odor.
Molecular Weight
130.2
Boiling Point
327°F
Freezing Point
?
Solubility
2%
Vapor Pressure
(77°F): 3 mmHg
Ionization Potential
?
Specific Gravity
0.91
Flash Point
130°F
Upper Explosive Limit
?
Lower Explosive Limit
?
Class II Combustible Liquid: Fl.P. at or above 100°F and below 140°F.
Incompatibilities & Reactivities
Strong oxidizers, strong caustics
Exposure Routes
inhalation, ingestion, skin and/or eye contact
Symptoms
irritation eyes, skin, nose; skin sensitization; narcosis; possible hematopoietic effects; central nervous system depression
Target Organs
Eyes, skin, respiratory system, central nervous system, blood
Personal Protection/Sanitation
(See protection codes)
Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated
Remove:When wet or contaminated
Change:No recommendation
First Aid
(See procedures)
Eye:Irrigate immediately
Skin:Soap wash immediately
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations

NIOSH

Up to 56 ppm:
(APF = 10) Any chemical cartridge respirator with organic vapor cartridge(s)*
(APF = 10) Any supplied-air respirator*

Up to 140 ppm:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode*
(APF = 25) Any powered, air-purifying respirator with organic vapor cartridge(s)*

Up to 250 ppm:
(APF = 50) Any chemical cartridge respirator with a full facepiece and organic vapor cartridge(s)
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s)*
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece

Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus

Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister
Any appropriate escape-type, self-contained breathing apparatus

Important additional information about respirator selection

See also
INTRODUCTION   ICSC CARD: 0115
Page last reviewed: October 30, 2019