p-Anisidine

Synonyms & Trade Names
para-Aminoanisole, 4-Anisidine, p-Methoxyaniline
CAS No.
104-94-9
RTECS No.
DOT ID & Guide
2431 153
Formula
NH₂C₆H₄OCH₃
Conversion
IDLH
50 mg/m3
See: 104949
Exposure Limits
NIOSH REL
TWA 0.5 mg/m3 [skin]
OSHA PEL
TWA 0.5 mg/m3 [skin]
Measurement Methods
NIOSH 2514
See: NMAM or OSHA Methods
Physical Description
Yellow to brown, crystalline solid with an amine-like odor.
Molecular Weight
123.2
Boiling Point
475°F
Melting Point
135°F
Solubility
Moderate
Vapor Pressure
(77°F): 0.006 mmHg
Ionization Potential
7.44 eV
Specific Gravity
1.07
Flash Point
?
Upper Explosive Limit
?
Lower Explosive Limit
?
Combustible Solid
Incompatibilities & Reactivities
Strong oxidizers
Exposure Routes
inhalation, skin absorption, ingestion, skin and/or eye contact
Symptoms
headache, dizziness; cyanosis; red blood cell Heinz bodies
Target Organs
Blood, kidneys, liver, cardiovascular system, central nervous system
Personal Protection/Sanitation
(See protection codes)
Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated
Remove:When wet or contaminated
Change:Daily
Provide:Quick drench
First Aid
(See procedures)
Eye:Irrigate immediately
Skin:Soap wash immediately
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations

NIOSH/OSHA

Up to 5 mg/m3:
(APF = 10) Any particulate respirator equipped with an N95, R95, or P95 filter (including N95, R95, and P95 filtering facepieces) except quarter-mask respirators. The following filters may also be used: N99, R99, P99, N100, R100, P100.
Click here for information on selection of N, R, or P filters.
(APF = 10) Any supplied-air respirator

Up to 12.5 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode
(APF = 25) Any powered, air-purifying respirator with a high-efficiency particulate filter.

Up to 25 mg/m3:


(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters. 


(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter*
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece

Up to 50 mg/m3:
(APF = 1000) Any supplied-air respirator operated in a pressure-demand or other positive-pressure mode*

Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus

Escape:


(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters. 


Any appropriate escape-type, self-contained breathing apparatus

Important additional information about respirator selection

See also
INTRODUCTION   ICSC CARD: 0971
Page last reviewed: October 30, 2019